What was found
AFT PIT FLOOR PANEL SPLICE BETWEEN 2 AND 3 HAS CORR. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS FABRICATED NEW TEE IAW SRM 53 00 53 1A 2 AND SRM 51 40 05 0G 0 W 1 O .07 R .05 L 2 D .02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FLOOR PANEL SPLICE BETWEEN 2 AND 3 HAS CORR. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS FABRICATED NEW TEE IAW SRM 53 00 53 1A 2 AND SRM 51 40 05 0G 0 W 1 O .07 R .05 L 2 D .02.