What was found
AFT WET AREA STA 947.5 HAS AREA OF CORR AT LBL 53. GROUNDED - YES. REPAIRED FLOORBEAM UPPER FLANGE IAW SRM 53 70 51 2R 5 W 1" O .180 R .138 L 1" D .042".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT WET AREA STA 947.5 HAS AREA OF CORR AT LBL 53. GROUNDED - YES. REPAIRED FLOORBEAM UPPER FLANGE IAW SRM 53 70 51 2R 5 W 1" O .180 R .138 L 1" D .042".