What was found
MULTIPLE AREAS OF CORR ON FS 986.5. GROUNDED - YES. REPAIRED 986.5 FLOORBEAM IAW SRM 53 70 51 2R 4 W 3.0 O .150 R .110 L 3.0 D .040.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MULTIPLE AREAS OF CORR ON FS 986.5. GROUNDED - YES. REPAIRED 986.5 FLOORBEAM IAW SRM 53 70 51 2R 4 W 3.0 O .150 R .110 L 3.0 D .040.