What was found
CONT CAB ZONE TEMP LIGHT ILLUMINATED ON MASTER RECALL. GROUNDED - YES. RELEASED PER MEL 21-21G FLIGHT DECK PRIMARY TEMP CONTROL INOP. VERIFIED FAULT, CLEANED ALL 3 TEMP SENSOR FILTERS. ACCOMP PACK ZONE TEMP CONT BITE TEST, CONTROLLER NR 1 NO FAULTS, CONTROLLER NR 2 SHOWS FLT DECK TRIM VALVE FAULT. CLEARED FAULT. ACCOMP PACK/ZONE TEMP CONT BITE TEST, TEST NOW PASSES NO FAULTS. REF AMM 21-61-20-860-005, AMM 21-61-06-100-801. A/C RELEASED FROM MEL 21-21G.