EMERGENCY LIGHT ON L1 AND R1 DOOR INOP GROUNDED - YES. REMOVED AND REPLACED EPSU 10WL WITH NEW BATT. IAW AMM 33-51-38 , UNIT BITE TEST OK. PERFORMED EPSU SYS TEST , TEST OK. NO FAULT NOTED. ALL EMER. LIGHTS COMES ON. NO FAULT NOTED, OPS CHECK GOOD. PSU P/N OFF : 772-338-00 S/N OFF : 008985 PSU P/N ON : 772-338-00 S/N ON : 009108