Service difficulty report · Warning Light · Boeing 737890

Difficulty date
March 29, 2019
Submitted
April 1, 2019
Operation
Air carrier
Aircraft
N512AS
Make and model
Boeing 737890
Aircraft serial
39043
Aircraft time
40,718 hours, 12,228 cycles
Part
Warning Light
Condition
False Activation
Location
Aft Zone Temp
Stage of operation
NR
How discovered
9
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFT ZONE TEMP LIGHT ILLUMINATED ON RECALL. EXTINGUISHED ON MASTER CAUTION RESET. GROUNDED - YES. INITIALLY HAD FAULT FOR AFT CABIN TRIM MODULATING VALVE. RESET SYSTEM AND RAN BOTH PACKS FOR 30 MINUTES, VARIED SUCCESSFULLY TEMPERATURE FOR ALL ZONES. AFTER RUNNING BOTH PACKS FOR 30 MINUTES, NO FAULTS AFTER RECALL BUTTON PUSHED. GROUND VERIFICATION CHECK WAS GOOD IAW AMM 21-61-21-400-801. BOTH CONTROLLERS BITE CHECK GOOD AFTER PACKS RUN.