Service difficulty report · Sensor · Airbus A320214

Difficulty date
April 14, 2019
Submitted
April 15, 2019
Operation
Air carrier
Aircraft
N281VA
Make and model
Airbus A320214
Aircraft serial
06669
Aircraft time
12,907 hours, 4,228 cycles
Part
Sensor
Condition
Malfunctioned
Location
Bleed Sys
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CLASS II AIR BLEED FAULT ( FAULTING LEFT WING LOOP A. DO NOT REPLACE BMC. BMC WAS REPLACED ON 3/16/2019) GROUNDED - YES. REMOVED AND REPLACED SENSING ELEMENT 31HF, 73HF AND 90HF PER AMM 36-22-18-000-001-A, AMM 36-22-18-400-001-A, AMM 36-22-18-000-802-A AND AMM 36-22-18-400-802-A. PERFORMED GOOD ENGINE AUTOMATIC START FOR BOTH ENGINES PER AMM 71-00-00-710-003-B. THIS CLEARS MDDR 65440, SEAMC DARWIN NOTIFIED, PLACARD REMOVED. R3651630