Service difficulty report · Control Valve · Boeing 737890

Difficulty date
April 23, 2019
Submitted
April 26, 2019
Operation
Air carrier
Aircraft
N513AS
Make and model
Boeing 737890
Aircraft serial
35192
Aircraft time
40,417 hours, 12,051 cycles
Part
Control Valve
Part number
3989083
Part serial
8890
Condition
Stuck
Location
Rt A/C Pack
Part time
46,989 hours, 14,019 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT PACK LIGHT ON UPON MASTER CAUTION RECALL LIGHT EXTINGUISHES UPON MASTER CAUTION RESET. GROUNDED - YES. REF L/P 11972111, TCV 2 (V141) FAILED BITE TEST. REMOVED & REPLACED TCV 2 REF B737-800 AMM 21-51-10. ACCOMPLISHED PACK-ZONE TEMP CONTROLLER BITE TEST REF AMM 21-61-00-700-806-002, OPS CK NML. ALSO, RAN BOTH PACKS ON APU, GROUND FUNCTIONAL CK NML. MASTER CAUTION RECALL PRESSED NUMEROUS TIMES, RT PACK LIGHT DOES NOT COME ON. AIRCRAFT RELEASED FROM MEL 21-32B.