What was found
LEFT PACK LIGHT ILLUMINATED UPON DESCENT, IT EXTINGUISHED UPON RECALL. GROUNDED - YES. RESET BOTH #1 AND #2 PACK/ZONE TEMPERATURE CONTROLLERS, RAN BITE CHECKS ON BOTH CONTROLLERS, OPS CHECK GOOD IAW AMM 21-61-00-700-806-002, THEN RAN BOTH PACKS (LT AND RT) FOR 30 MINUTES, NO ISSUES, NO PROBLEMS. RAN BITE TEST AGAIN ON #1 AND #2 PACK/ZONE TEMPERATURE CONTROLLERS, OPS CHECK GOOD AGAIN.