What was found
ENG #2 LOOP A TEST INOP. GROUNDED - YES. PERFORMED M279 BITE REF 26-10 TASK 801. NO FAULTS LOGGED FOUND. ACCOMPLISHED ENGINE - WIRING HARNESS/FIRE DETECTOR - FAULT ISOLATION 26-10 TASK 805. ALL READINGS FOUND WITHIN LIMITS. DUE TO LONG HISTORY OF #2 ENG A LOOP FAULTS. PRECAUTIONARY REPLACED 3 FIRE DETECTORS M1757 A/B LOOP, M1759 A/B LOOP, M1760 A/B LOOP. REF 26-11-01. PERFORMED OPS TEST 26-11-00-710-801. ALL TESTS PASSED.