What was found
FWD PIT LT ZEE CHANNEL IS CORRODED @ BS500I. GROUNDED - YES. REMOVED AND INSTALLED NEW ZEE CHANNEL AND SPLICE PLATE STA BS5001 IAW SRM 53-00-53. REMOVED CORR. FROM ZEE CHANNEL ORIG. THICKNESS .040 IAW SRM 53-530-53 MAT. LOSSED .010 REMAINING THICKNESS.030 FOUND OUT OF LIMITS IAW SRM 53-00-53. LOCATED, DRILLED AND TRIMMED NEW ZEECHANNEL AND SPLICE PLATE IAW SRM 53-00-53-20-5 REPAIR 5 FIG 202 SHEET 1. ALODINED IAW AMM 51-21-41. PRIMED IAW AMM 51-21-72. PAINTED IAW AMM 51-21-92.