What was found
RT PACK ANNUNCIATOR ILLUMINATED ON RECALL - RESET PACK AND MASTER BUT LIGHT REMAINED ILLUMINATED. GROUNDED - YES. PERFORMED BITE CK, GREEN GO LIGHT ILLUMINATED, RAN RT PACK FOR 5 MIN, REACCOMPLISHED BITE CK, RT PACK TCV FAULTED, ISOLATED FAULT TO THE RT PACK TRIM AIR MODULATING VALVE, REPLACED VALVE PER AMM 21-61-21-00-801, REACCOMPLISHED BITE CK PER AMM 21-61-00-700-806-002, GREEN GO LIGHT ILLUMINATED.