Service difficulty report · Wire · Boeing 737890

Difficulty date
August 10, 2019
Submitted
August 12, 2019
Operation
Air carrier
Aircraft
N566AS
Make and model
Boeing 737890
Aircraft serial
35182
Aircraft time
48,092 hours, 14,364 cycles
Part
Wire
Condition
Misinstalled
Location
Transformer
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

R2 WINDOW HEAT OVERHEAT LIGHT ILLUM ON SHORT FINAL AT NIGHT. GROUNDED - YES. WHCU FAULTS WINDOW SENSOR. SENSOR RESISTANCE NORMAL, WIRING FROM WINDOW TO WHCU NORMAL. FOUND HEAT LEAD ON TRANSFORMER TERM 2, SHOULD BE ON TERM 1 FOR H16 REF B737-800 WDM 30-41-11. RELOCATED HEAT LEAD TO TERM 1. OPS CHECK GOOD PER B737-800 AMM 30-41-00-710-801.