What was found
WHILE ACCOMPLISHING CARD ATG4-RMV-320-13, FOUND FRAME 28 PUNCTURED IN 2 PLACES BETWEEN STRINGER 2L TO 4L GROUNDED - YES. ACCOMPLISHED EA A320-53 EA-00103 REV OO, REVISION DATE 09/20/2019. REPAIR APPROVED AS CATEGORY B PER RDAS 80681012/003/2019 ISSUE A DATED 20/SEPT/2019 WITH THRESHOLD OF 60,000 FC / 120,000 FH WITH INTERVAL AND METHOD OF INSPECTION TBD.