What was found
AIR PACK 2 REGULATOR FAULT. GROUNDED - YES. RESET PACK 2 AND PERFORMED BITE TEST OF PACK 2 TEMP CONTROL. TEST OK. OPERATED PACKS WITH APU BLEED. NO FAULTS OR WARNINGS. REF AMM 21-63-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIR PACK 2 REGULATOR FAULT. GROUNDED - YES. RESET PACK 2 AND PERFORMED BITE TEST OF PACK 2 TEMP CONTROL. TEST OK. OPERATED PACKS WITH APU BLEED. NO FAULTS OR WARNINGS. REF AMM 21-63-00.