What was found
ELEC P5 PANEL HAS ELEC LIGHT ILLUMINATED. GROUNDED - YES. BITE SHOWS STATIC INVERTER FAILED. WOULD NOT RESET. REPLACED THE STATIC INVERTER. OPS CHECKED GOOD. IAW AMM 24-34-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELEC P5 PANEL HAS ELEC LIGHT ILLUMINATED. GROUNDED - YES. BITE SHOWS STATIC INVERTER FAILED. WOULD NOT RESET. REPLACED THE STATIC INVERTER. OPS CHECKED GOOD. IAW AMM 24-34-21.