Service difficulty report · Valve · Boeing 737890

Difficulty date
October 5, 2019
Submitted
October 8, 2019
Operation
Air carrier
Aircraft
N519AS
Make and model
Boeing 737890
Aircraft serial
36482
Aircraft time
40,486 hours, 12,022 cycles
Part
Valve
Part number
3989083
Part serial
7067
Condition
Overheated
Location
Lt A/C Bay
Part time
51,450 hours, 24,644 cycles
Stage of operation
NR
How discovered
O
Nature of condition
M, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ZONE TEMP FLT DECK (CONT CAB) ILLUMINATED ON RECALL, EXTINGUISHES ON MASTER CAUTION RESET. GROUNDED - YES. CONFIRMED FAULT, "CONT CAB" ZONE TEMP LIGHT COMES ON EVERYTIME, RECALL PRESSED. R/H PACK/ZONE TEMP CONTROLLER SHOWS HARD FAIL "FLT DECK TCV" (V143). GVI V143, SHOWS OVERHEATING. L/H SIDE OK. REMOVED & REPLACED "FLT DECK TCV" REF B737-800 AMM 21-61-21. ACCOMPLISHED R/H PACK/ZONE TEMP CONTROLLER BITE REF AMM 21-61-00-700-806-002, LK CK & OPS CK NML.