As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CLIMB ECAM - AIR ENG 2 BLEED FAULT GROUNDED - YES. COMPLETED RMA 3391 - PERFORMED TEST OF THE FAN AIR VALVE AND SENSE LINE PER AMM AMM 36-11-00NO DEFECT NOTED REMOVED + REPLACE FAN AIR VALVE THERMASTAT PER AMM 36-1-43 OPS CHECK GOOD - ACFT RETURNED NORMAL CONFIGUATION