What was found
ON CLIMBOUT ECAM SHOWED AIR ENG 1 BLEED FAULT GROUNDED - YES. PERFORMED BITE OF BMC1 REF AMM 36-11-00-740-001-A , TEST OK. NO FAULT CURRENTLY , NO HISTORY 30 DAYS , SEAMC CONTACTED PER LOGPAGE 8052445: VERIFIED ENG 1 BLEED INOP. EACH MX PROCEDURE CONTAINED IN THE MEL WAS ACCOMPLISHED. RELEASED PER MEL 36-11-01-02-A. MEL LOG UPDATED.