What was found
AFTER 2 FADEC START ATTEMPTS OF # 1 ENGINE RECEIVED "ENG 1 IGN A" INOP STATUS MSSG. (BOTH ENGINES AUTOMATICALLY STARTED SUCCESSFULLY ON IGN B). MEL 74-31-01-01-C. GROUNDED - YES. R & R ENG #1 IGNITER SYS A IAW AMM 74-21-10 PB 401 OPS CHK GOOD , A/C RELEASED FROM MEL 74-31-01-01 -C MAINT PROCEDURES REVERSED, MDDR 73540 REMOVED, LOG UPDATED, PLACARD REMOVED MCC JACK NOTIFIED