Service difficulty report · Actuator · Boeing 737890

Difficulty date
December 3, 2019
Submitted
December 10, 2019
Operation
Air carrier
Aircraft
N519AS
Make and model
Boeing 737890
Aircraft serial
36482
Aircraft time
41,103 hours, 12,200 cycles
Engine
Cfmint CFM567B27
Part
Actuator
Part number
1211313010
Part serial
AM150
Condition
Out Of Limits
Location
Nr 1 V/Stator
Part time
2,032 hours, 552 cycles
Stage of operation
IN
How discovered
O
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE PERFORMING T/C 78273000 FOUND FAULT CODE 75-30401 VSV POSITION SIGNALS DISAGREE SHORT TIME FAULT DEFERRED PER T/C 78273000. GROUNDED - YES. ACCOMPLISHED T/C 78273000 FAULT MSG 75-30401 (THE VSV POSITION SIGNALS DISAGREE) IS NO LONGER ACTIVE, FAULT CODE 75-10391 IS ACTIVE (VSV POSITION SIGNAL IS OUT OF RANGE ) REF LOG PAGE 12106108. PERFORMED B737-800 FIM 75-31 TASK 804 AND FIM 75-31 TASK 803, RESISTANCE CHECKS ARE GOOD ACTUATOR TEST IS GOOD, EEC TEST IS GOOD. FAULT 75-10391 IS ACTIVE ON EVERY LEG. REMOVED AND REPLACED #1 ENGINE RIGHT HAND VSV ACTUATOR REF B737-800 AMM 75-31-01 / 801-F00. OPS AND LEAK TEST GOOD , NO FAULTS FOUND. GROUND VERIFICATION COMPLETED.