Service difficulty report · Shutoff Valve · Boeing 737890

Difficulty date
December 7, 2019
Submitted
December 10, 2019
Operation
Air carrier
Aircraft
N519AS
Make and model
Boeing 737890
Aircraft serial
36482
Aircraft time
41,140 hours, 12,209 cycles
Part
Shutoff Valve
Part number
AV16E1209D
Part serial
AA170186
Condition
Inoperative
Location
Apu Fuel
Part time
41,139 hours, 12,204 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APU FAULT LT ILLUMINATED A FEW MINUTES AFTER SHUTTING APU OFF. GROUNDED - YES. ACCOMPLISHED BITE CK ON APU REF B737-800 FIM 49-60 TASK 801. MAINT MESSAGE 49-31001 APU FUEL VALVE SHUTDOWN DISPLAYED. FOLLOWED FIM 49-30 TASK 801. APU FUEL VALVE FAILED IN OPEN OR "ON" POSITION. RELEASED PER MEL 28-4B. APU FUEL VALVE INOP. REMOVED AND REPLACED APU FUEL SHUTOFF VALVE ACTUATOR REF B737-800 AMM TASK 28-25-02-400-801 PER PRIOR TROUBLESHOOTING. OPS CHECK GOOD. ETOPS GROUND VERIFICATION SUCCESSFUL. THIS CLEARS MEL 28-4B.