As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT "PACK" LIGHT ILLUMINATES DURING MASTER CAUTION RECALL. LIGHT EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. GROUNDED - YES. PERFORMED FIM 21-53 TASK 821, PACK LIGHT IS ON DURING MASTER CAUTION RECALL. PACK LIGHT ON AIR COND. MODULE P5-10, DOES NOT COME ON, THEN THERE AN INTERMITTENT FAULT, OK FOR SERVICE. NO HISTORY ON RIGHT HAND PACK FOR 30 DAYS. PERFORMED FIM TASK 21-62 TASK 801 ALL FAULTS CLEARED AND NO DEFECTS NOTED.