Service difficulty report · Modulating Valve · Boeing 737890

Difficulty date
December 16, 2019
Submitted
December 20, 2019
Operation
Air carrier
Aircraft
N579AS
Make and model
Boeing 737890
Aircraft serial
35187
Aircraft time
48,526 hours, 14,432 cycles
Part
Modulating Valve
Part number
3989083
Part serial
8252
Condition
Inoperative
Location
Cockpit Temp
Part time
48,324 hours, 16,832 cycles
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONTROL CABIN TEMP SELECTOR ADJUSTED TO NEAR FULL WARM POSITION, ABLE TO INCREASE/DECREASE TEMP ON SUPPLY DUCT GAUGE BUT FLIGHT DECK CONTINUES TO BE VERY COLD. GROUNDED - YES. REMOVED & REPLACED FLIGHT DECK TCV (V143) PER B737-800 AMM 21-61-21, LK CK & OPS CK NML. PULLED & RESET 1 TOTAL C/B. ALSO, REMOVED & REPLACED TEMPERATURE CONTROL MODULE (P5-17) AS PRECAUTIONARY REF AMM 21-61-15. PULLED & RESET 4 TOTAL C/BS. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER (R/H) BITE TEST REF AMM 21-61-00-700-806-002, GROUND VERIFICATION CK NML. VERIFIED CORRECT PARTS EFFECTIVITY REF IPC 21-61-07-03 & IPC 21-61-21-02.