Service difficulty report · Sensor · Boeing 737890

Difficulty date
December 21, 2019
Submitted
December 24, 2019
Operation
Air carrier
Aircraft
N531AS
Make and model
Boeing 737890
Aircraft serial
35199
Aircraft time
37,261 hours, 10,906 cycles
Engine
Cfmint CFM567B27
Part
Sensor
Part number
9325M15G02
Condition
Faulted
Location
Nr 2 Engine
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE PERFORMING TASK CARD 78273000 HAD LONG TERM FAULT #2 ENGINE 75-20832 "THE T3 SIGNAL IS OUT OF RANGE". GROUNDED - YES. REMOVED PRECOOLER UPSTREAM DUCT REF AMM 36-12-01-000-801. REPLACED T3 SENSOR IAW AMM TASK 73-21-07-000/400-801-F00. PERFORMED EEC TEST IAW AMM 73-21-00-804-F00. EEC TEST PASSES. FAULT STILL SHOWS IN FAULT HISTORY. REINSTALLED PRECOOLER UPSTREAM DUCT REF AMM 36-12-01-400-802.