What was found
MAIN CABIN, TOP BEAM CORRODED AT FRAME 66 AT APPROX -Y1500. GROUNDED - YES. REMOVED CORROSION OF DAMAGED AREA BY ENLOGATION FASTNER HOLE TO MAX SIZE, AND DAMAGE WAS STILL PRESENT AREA FOUND TO BE OUT OF LIMITS IAW A319 SRM 51-41-14, FABRICATED (MACHINED) REPAIR ANGLES IAW SRM 53-41-14-300-001, CUT OUT REMAINING DAMAGED AREA IAW SRM 51-41-14. REMOVED FWD GIRT BAR FITTING TO F.O.M. IAW SRM 51-41-14. FABRICATED REPAIR IAW SRM 53-41-14-300-001-FIG 001. ALODINED REPAIR IAW SRM 51-21-11, PRIMED IAW A319 SRM 51-21-11 AND INSTALLED REPAIR IAW SRM 51-41-14. TOPCOATED REPAIR IAW SRM 51-91-11 AND RE-INSTALLED GIRT BAR FITTING IAW SRM 51-41-14. THIS IS A CAT A REPAIR