Service difficulty report · Sensor · Boeing 737890

Difficulty date
February 8, 2020
Submitted
February 11, 2020
Operation
Air carrier
Aircraft
N565AS
Make and model
Boeing 737890
Aircraft serial
35181
Aircraft time
50,712 hours, 15,164 cycles
Part
Sensor
Condition
Dirty
Location
Temp Sensor
Stage of operation
NR
How discovered
V
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONT CAB ZONE TEMP LIGHT COMES ON WITH RECALL, IT GOES OUT WHEN MASTER CAUTION IS RESET. GROUNDED - YES. PERFORMED PACK ZONE TEMPERATURE CONTROLLER BITE TEST PER AMM 21-51-00-700-803. #2 CONTROLLER FAULT FLT DECK TRIM VALVE. ACFT RELEASED ON MEL 21-21G. UNABLE TO DUPLICATE DEFECT OR PREVIOUS FINDING. PACK/ZONE TEMP CONTROLLER BITE PER B737-800 FIM 21-62 TASK 801 SHOWED NO FAULTS AND VERIFY TEST PASSED WITH NO FAULTS. DUE TO PREVIOUS FINDING, ACCOMPLISHED INITIAL EVALUATION FOR FLIGHT DECK TRIM VALVE FAULT PER FIM 21-62 TASK 832 - VERIFY TEST AGAIN PASSED WITH NO FAULTS. FOUND CONTROL CABIN TEMP SENSOR FILTER CLOGGED WITH DUST. REMOVED AND REPLACED FILTER PER B737-800 AMM 21-61-06-000-801/AMM 21-61-06-400-801 AND PERFORMED CABIN TEMPERATURE CONTROL AND INDICATION OPERATIONAL TEST PER AMM 21-61-00-700-807-002 - ALL TESTS PASS.