What was found
CORROSION ON FLOOR STRUCTURE IN FWD WET AREA AT FS 344 AND LBL12. GROUNDED - YES. REMOVED CORR FLOOR STRUCTURE FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED PART IAW B737 800 SRM 51 40 02 0G 0 W 1.5 O .080 R .063 L 1.25 D .017.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR STRUCTURE IN FWD WET AREA AT FS 344 AND LBL12. GROUNDED - YES. REMOVED CORR FLOOR STRUCTURE FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED PART IAW B737 800 SRM 51 40 02 0G 0 W 1.5 O .080 R .063 L 1.25 D .017.