What was found
#2 ENGINE NO N2 ROTATION OR INDICATION AFTER START SWITCH SET TO GRD. GROUNDED - YES. VERIFIED #2 STARTER NOT ROTATING WHEN START VALVE OPENED. REMOVED STARTER, INSPECTED CHIP DETECTOR W/> MODERATE DEBRIS > 0.10". NO PARTICLES PRESENT AFT OF QAD ADAPTER. INSTALLED NEW STARTER (AFTER PRE-OILING). ACCOMPLISHED POWER PLANT TEST 1 AND 3A W/ NO OIL/PNEUMATIC LEAKS OBSERVED. AFTER ENGINE RUN, NO DEBRIS FOUND IN STARTER CHIP DETECTO. REF. AMM 80-11-01/301 /601 /401. ETOPS GROUND VERIFICATION SUCCESSFUL.