What was found
RAMP REPORTS DENT NEAR AFT L/H FUSELAGE, FR 59 THRU FR 60 STRG 39-40, MEASURES 0.017" DEEP. 1.5" FROM FR. GROUNDED - YES. EVALUATED DENT, DEPTH .009, LENGTH 1.00, WIDTH 1.3, NEAREST STIFFNER 1.6, LOCATION BETWEEN FR 59 AND FR 60 AND STR 36L AND STR 40L AT WATERLINE -Z2000 FOUND TO BE WITHINLIMITS, HFEC AND DVI, NO DEFECTS NOTED REF A320 SRM 53-00-11-283-005 AND 53-41-11-283-002. THIS IS A CAT B REPAIR INSPECTION THRESHOLD FROM ADL 60,000 FC, 120.000 FH, INTERVAL TBD, METHOD TBD NOTIFIED SEAMC LAMANT,THIS CLOSES PLT DEFERRAL