What was found
ACCOMPLISHED VISUAL INSPECTION REF T/C NR/ 00002, FOUND DENT TO GO ACROSS STRINGER 23L STA 786 OUT OF LIMITS IAW 737 900ER SRM 53 00 01 1A 1 TABLE 103. GROUNDED - YES. REPAIRED FUSELAGE SKIN IAW 737 900 SRM 53 00 01 2R 1 THIS IS A CAT. B REPAIR WITH AN INSPECTION THRESHOLD OF 50,000 FLT. CYCLES AND INSPECTION INTERVAL OF EXTERNAL DETAILED VISUAL OF 4,000 CYCLES. A/C TOTAL CYCLES AT TIME OF REPAIR 3,868. RON AT SEAMC NOTIFIED.