What was found
ON RECALL AFTER START CHECK, LT PACK ILLUMINATED. RESET W/MASTER CAUTION PRESS. GROUNDED - YES. PZTC NR 1 BITE FAULTED "THIS PACK TCV" FIM 21-62 TASK 801, FAULT RESET PER FIM 21-62 TASK 831, OPS BOTH PACKS FOR 30 MINUTES, FULL COOL & FULL WARM, RECALL TEST & PZTC BITE TEST PASSED NO FAULT ACTIVE AMM 21-00-00, CLEARS MEL 21-32B.