Service difficulty report · Control Valve · Boeing 737890

Difficulty date
September 29, 2020
Submitted
September 30, 2020
Operation
Air carrier
Aircraft
N538AS
Make and model
Boeing 737890
Aircraft serial
41188
Aircraft time
31,921 hours, 9,343 cycles
Part
Control Valve
Part number
3989083
Part serial
6700
Condition
Faulted
Location
Rt A/C Pack Temp
Part time
54,228 hours, 23,127 cycles
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON TAXI OUT RIGHT PACK LIGHT ILLUMINATED, WOULD NOT RESET WHILE PERFORMING QRH PROCEDURE. JUST TO COMING INTO THE GATE LIGHT EXTINGUISHED, BUT THEN WOULD RE-ILLUMINATE ON RECALL. GROUNDED-YES. PERFORMED BITE PROCEDURE, PER B737-800 AMM 21-61-00. TCV FAULTED, REPLACED RT PACK TCV, PER AMM 21-51-10. PERFORMED BITE PROCEDURE, GREEN GO LIGHT ILLUMINATED. GROUND VERIFICATION SUCCESSFUL.