Service difficulty report · Modulating Valve · Boeing 737890

Difficulty date
November 3, 2020
Submitted
November 5, 2020
Operation
Air carrier
Aircraft
N585AS
Make and model
Boeing 737890
Aircraft serial
35683
Aircraft time
48,733 hours, 14,700 cycles
Part
Modulating Valve
Part number
3989085
Part serial
11284
Condition
Faulted
Location
Rt A/C Pack
Part time
43,306 hours, 13,199 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT PACK LIGHT ILLUMINATES ON RECALL. GROUNDED-YES. REPEAT WRITE UP, PERFORMED BITE CHECK OF NR 2 TEMP CONTROLLER, FOUND "THIS PACK TCV" FAULT LATCHED ON BIT AND LAST FLT, REPEAT FAULT. REMOVED AND REPLACED RT PACK TCV, REF B737-800 AMM 21-21-10. OPERATIONS CHECK GOOD. NO LEAKS OR FAULTS NOTED.