What was found
RIGHT PACK LIGHT ILLUMINATES ON RECALL. GROUNDED-YES. RT ZONE TEMP CONTROLLER LOGGED TCV FAULT. REMOVED AND REPLACED RT PACK TEMP CONTROL VALVE, REF B737-900 AMM 21-51-10. OPERATIONS CHECK GOOD. LEAK CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT PACK LIGHT ILLUMINATES ON RECALL. GROUNDED-YES. RT ZONE TEMP CONTROLLER LOGGED TCV FAULT. REMOVED AND REPLACED RT PACK TEMP CONTROL VALVE, REF B737-900 AMM 21-51-10. OPERATIONS CHECK GOOD. LEAK CHECK GOOD.