Service difficulty report · Connector · Boeing 737890

Difficulty date
March 5, 2021
Submitted
March 9, 2021
Operation
Air carrier
Aircraft
N588AS
Make and model
Boeing 737890
Aircraft serial
35685
Aircraft time
47,690 hours, 14,211 cycles
Engine
Cfmint CFM567B27
Part
Connector
Condition
Detached
Location
Nr 1 Engine
Stage of operation
IN
How discovered
9
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE ACCOMPLISHING TC 78273000 # 1 ENG. MAINT. FAULT 73-30901 T12 SIGNAL DISAGREE. SHORT TIME FAULT. GROUNDED - YES. ACCOMPLISHED T/S FOR FAULT 73-30901 PER B737-800 FIM 73-26 TASK 805 - INITIAL EVALUATION (EEC TEST) CONFIRMED FAULT AND INPUT MONITORING SHOWED T12 SENSOR CHANNEL B INPUT AS DASHES. ACCOMPLISHED FAULT ISOLATION PROCEDURE FOR DUAL CHANNEL FAULT PER FIM PARAGRAPH G - FOUND CONNECTOR DJ0804J FOR T12 SENSOR CHANNEL B OUTPUT NOT CONNECTED TO BULKHEAD RECEPTACLE. CLEANED AND INSPECTED CONNECTOR - NO DEFECTS NOTED AND THREADS ON CONNECTOR AND RECEPTACLE WERE SERVICEABLE. REINSTALLED AND SECURED T12 CHANNEL B CONNECTOR, CHECKED CHANNEL A CONNECTOR FOR SECURITY, AND PERFORMED EEC TEST PER B737-800 AMM 73-21-00-700-804-F00 - ALL TESTS PASS. INPUT MONITORING SHOWS NORMAL INPUT FROM T12 SENSOR CHANNELS A AND B.