Service difficulty report · Hmu · Boeing 737890

Difficulty date
March 21, 2021
Submitted
March 30, 2021
Operation
Air carrier
Aircraft
N535AS
Make and model
Boeing 737890
Aircraft serial
35200
Aircraft time
37,326 hours, 10,754 cycles
Engine
Cfmint CFM567B27
Part
Hmu
Part number
1853M56P12
Part serial
BECW6840
Condition
Faulted
Location
Nr 2 Engine
Part time
39,268 hours, 13,462 cycles
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

REF. TC #78273000. #2 ENGINE HAS SHORT TIME FAULT, 73-20342 "FMV POSITION SIGNAL IS OUT OF RANGE.". GROUNDED - YES. ACCOMPLISHED B737-800 FIM 73-25 TASK 803. FAULT MESSAGE 73-20342 IS STILL ACTIVE. AT HMU RECEPTACLE DP0601 PIN 16-TO 34IS AT 14.4 MEG OHMS SHOULD BE 36-91 OHMS. WIRE HARNESS FROM DP0601 TO DP0606IS GOOD AND DP0501TO DP0505 IS GOOD. PER FIM 73-25TASK 803 STEP F(4)(A)SAY TO REPLACE HMU. REMOVED AND REPLACED HMO PER T/C N8473000 AND N8473001.LEAK CHECK AND OPS CHECK NORMAL FAULT 73-20342 DID NOT RETURN.