Service difficulty report · Modulating Valve · Boeing 737890

Difficulty date
March 30, 2021
Submitted
April 1, 2021
Operation
Air carrier
Aircraft
N566AS
Make and model
Boeing 737890
Aircraft serial
35182
Aircraft time
52,611 hours, 15,562 cycles
Part
Modulating Valve
Part number
3989083
Part serial
9354
Condition
Inoperative
Location
Left Ecs Bay
Part time
48,537 hours, 14,449 cycles
Stage of operation
CL
How discovered
V
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONT CAB ZONE TEMP LIGHT ILLUMINATED AFTER TAKEOFF. RAN QRH, LIGHT RESETS WITH MASTER CAUTION RESET. GROUNDED - YES. DUE TO PAST HISTORY REMOVED AND REPLACED CONTROL CABIN TRIM MODULATING VALVE IAW B737-800 AMM 21-61-21-000-801 AND AMM 21-61-21-400-801, ETOPS GROUND FUNCTIONAL CHECK GOOD IAW AMM 21-61-00-700-806-002.