What was found
FWD PIT R/H TRANSITION PANEL HAS AREA OF CORROSION STA 500H TO 500I. GROUNDED - YES. CORROSION FOUND TO BE OUT OF LIMITS, REPAIRED SIDEPLATE IAW B737-900 SRM 53-00-53-2R-5W=1.50" O=0.040" R=0.033" L=4.00" D=0.007".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT R/H TRANSITION PANEL HAS AREA OF CORROSION STA 500H TO 500I. GROUNDED - YES. CORROSION FOUND TO BE OUT OF LIMITS, REPAIRED SIDEPLATE IAW B737-900 SRM 53-00-53-2R-5W=1.50" O=0.040" R=0.033" L=4.00" D=0.007".