As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CABIN AFT GALLEY AREA FLOOR BEAM CORRODED AT Y512.5 BETWEEN FR70-FR69 GROUNDED - YES. REMOVED CORROSION AND CHECKED THE LIMITS. ORIGINAL THICKNESS IS .160, REMAINING IS .100, .060 WAS REMOVED . OUT OF LIMITS REF A320 SRM 53-00-14. REMOVED AND REPLACED BEAM REF AIRBUS DWG D53472780