What was found
R/H FWD SERVICE DOOR CUTOUT LOWER FWD CORNER HAS CORRODED AT FASTENER HOLE GROUNDED - YES. REMOVED 4 EACH WATER LINE CLAMPS, 4 EA HI-LOKS AND 1 EACH FLOOR BEAM BOLT TO FOM AS PER A320 SRM 51-42-11. REMOVED CORROSION AND FOUND TO BE WITHIN LIMITS AS PER A320 SRM 53-11-14. ACCOMPLISHED DVI AS PER A320 53-11-14. HFEC AS PER NTM 51-10-08. SPOT FACED 4 EACH AREAS AS PER A320-SRM 53-11-14 FIGURE 001, PARAGRAPH 7(B). ROTOPEENED AS PER NTM 51-10-01. MATERIAL ID FOR WASHERS AS PER A320 SRM 53-11-14. FABRICATED WASHERS AS PER A320 SRM 53-11-14-283-005. ACCOMPLISHED REPAIR PER AIRBUS A320 SRM 53-11-14. THIS IS A CATEGORY "B" REPAIR WITH AN INSPECTION THRESHOLD OF 60,000 FC REF A320 SRM 53-11-14-205-001 DOT REMOVED