What was found
AFT PIT L/H TRANSITION PANEL HAS CORROSION STA 727 TO 807. GROUNDED - YES. REPAIRED AFT PIT LH TRANSITION PANEL AT STA 727 TO 807 IAW B737-900 SRM 53-00-53-2R-JW= 3 O= .040 R= 0 L= 20 D= .040.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT L/H TRANSITION PANEL HAS CORROSION STA 727 TO 807. GROUNDED - YES. REPAIRED AFT PIT LH TRANSITION PANEL AT STA 727 TO 807 IAW B737-900 SRM 53-00-53-2R-JW= 3 O= .040 R= 0 L= 20 D= .040.