What was found
FLOOR WEBB PLATE HAS A CORROSION SPOT AT STA 986 LBL 32, IN THE AFT CABIN. GROUNDED - YES. LOCATED AND DRILLED NEW WEB IAW 737-800 SRM 51-40-05-0G-0 CORROSION REMOVAL WAS 100% MATL LOSS AND IS OUT OF LIMITS IAW 737-800 SRM 53-70-51-1A-1 PART WAS REMOVED AND MIG5 OK273681 NEW WEB WAS LOCATED AND DRILLED ON WORK BENCH IAW 737-800 SRM 51-40-08-0G-0 NEW PART TO BE INSTALLED ON MIG5 273681 AAR W/O 1019442 2000/0109W=1" O=.040 R=0 L=1" D=.040.