What was found
FLOOR Z-ZNGLE STRIP AT STA 992 HAS CORROSION SPOTS BETWEEN RBL 33 THRU RBL 44, IN THE AFT CABIN. GROUNDED - YES. LOCATED AND DRILLED NEW ZEE SUPPORT IAW 737-800 SRM 51-40-05-0G-0 CORROSION REMOVAL WAS 100% MATL LOSS AND IS OUT OF LIMITS IAW 737-800 SRM 53-70-51-1A-1 PART WAS REMOVED ON MIG5 OK273681 NEW ZEE SUPPORT WAS LOCATED AND DRILLED ON WORK BENCH IAW 737-800 SRM 51-40-05-0G-0 NEW PART TO BE INSTALLED ON MIG5 OK273681 AAR W/O 1019442 2000/0109W=1" O=.050" R=0" L=3" D=.050.