As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT FLOOR LANDING STRIP FOR PANEL 211AP HAS CORROSION SPOTS AT STA 268 VBETWEEN LBL 11 THRU RBL 11. GROUNDED - YES. REMOVED CORROISON, FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-10-51-1A-1. REPAIRED AREA IAW EA # 800-53EA-23741W= 1 1/2 O= .050 R= .040 L= 1" D= .010.