What was found
FOLLOW-UP TO #1 IDG CONTINUED FREQUENT SERVICING. REPLACE IDG FOR BENCH CHECK. (#PRI2/ETOPS). GROUNDED - YES. (RESOLVED ON W/O: 1881295 TASKCARD: N/R-00001 ) REMOVED AND REPLACED # 1 IDG REF AMM 24-11-11/401. OPS AND LEAK CHECK GOOD PER AMM 24-11-00-700-802. SERVICED IDG # 1 OIL TO CORRECT LEVEL REF AMM 12-13-21. PART NUMBER VERIFIED BY SEAMC JAKE.