986 BEAM HAS SPOTS OF CORROSION FROM LBL 45 TO RBL 45. GROUNDED - YES. REPAIRED FLOOR BEAM IAW 737-700 SRM 53-70-51-2R-6.W= 2" O= .150" R= .115" L= 2" D= .035".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
986 BEAM HAS SPOTS OF CORROSION FROM LBL 45 TO RBL 45. GROUNDED - YES. REPAIRED FLOOR BEAM IAW 737-700 SRM 53-70-51-2R-6.W= 2" O= .150" R= .115" L= 2" D= .035".