What was found
3 OF 5 EMERGENCY LIGHTS ON POWER SUPPLY M1670 INOP. GROUNDED - YES. REMOVED AND REPLACED M1670 BATTERY POWER SUPPLY IAW B737-800 AMM 33-51-06-960-806.OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
3 OF 5 EMERGENCY LIGHTS ON POWER SUPPLY M1670 INOP. GROUNDED - YES. REMOVED AND REPLACED M1670 BATTERY POWER SUPPLY IAW B737-800 AMM 33-51-06-960-806.OPS CHECK GOOD.