Service difficulty report · Valve · Boeing 737890

Difficulty date
October 27, 2021
Submitted
October 29, 2021
Operation
Air carrier
Aircraft
N594AS
Make and model
Boeing 737890
Aircraft serial
35191
Aircraft time
48,470 hours, 14,442 cycles
Part
Valve
Part number
3989085
Part serial
13608
Condition
Faulty
Location
Right Ecs Bay
Part time
39,605 hours, 12,151 cycles
Stage of operation
NR
How discovered
V
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT PACK LIGHT ILLUMINATED, EXTINGUISHES W/MASTER CAUTION RESET. GROUNDED - YES. PERFORMED NO 2 PACK ZONE TEMP CONTROLLER BITE REF B737-800 AMM 21-51-00-700803 "TCV" LIGHT ILLUMINATED FOR BIT AND PREV FLT MODE. NO FAULTS IN VERIFY MODE. REMOVED AND REPLACED #2 PACK TEMP CONTROL VALVE REF AMM 21-51-10. PART VERFIED ETOPS BY SEAMC JAROD. PERFORMED TEMP CONTROLLER BITE CHECK REF AMM 21-51-00, VERIFIED GOOD NO FAULTTHIS ACTION CLEARS MEL 21-32BC/N 27052594 REMOVED SEAMC JAROD NOTIFIED.