What was found
#1 FQIS FAILS SYSTEM TEST. COMPENSATOR PROBE F15 AND PROBES TU7, TU8, TU10, AND TU11 ARE OUT OF ACCEPTABLE CAPACITANCE VALUES. GROUNDED - YES. REMOVED AND REPLACED #1 FQIS COMPENSATOR PROBE AND PROBES TU7, TU8, TU10, AND TU11. ALL PROBES REPLACED PER B737-800 AMM 28-41-21/401 AND CAPACITANCE VALUES NOW READ GOOD. ALL ITEMS COMPLETE AND CLOSED. LEAK CHECK AND INSPECTION REQUIREMENTS. #1 FQIS OK FOR ETOPS SERVICE. FUEL LOAD BALANCED FOR DISPATCH.